Ponsonnas Church: what the wall moisture checks recorded
November 18, 2026
Saint-Égrève Church: readings from a STOP ONE ST60 follow-up
November 18, 2026The following reference concerns a public building. It helps an owner understand what a documented wall-drying follow-up contains, before looking at the devices suitable for a separate property.
The Pinsaguel château case concerns a heritage building equipped with three ATG GEOSTOP 60 devices, according to the clarification supplied by Humidistop. Installation took place on 26 January 2017; the control visit is dated 5 March 2019.
Readings and sampling conditions
| Sampling point | Initial reading | Control reading |
|---|---|---|
| Point 1 | 6.5 gr per 20 g | 2.5 gr per 20 g |
| Point 2 | 10.4 gr per 10 g, as printed | 2.3 gr per 20 g |
| Point 3 | 6.5 gr per 20 g | 2.5 gr per 20 g |
| Point 4 | 10.4 gr per 10 g, as printed | 1.7 gr per 20 g |
Points 1 and 3 are recorded at a height of 50 cm and a depth of 15 cm; points 2 and 4 at 42 cm and 15 cm. For points 2 and 4, the printed initial water mass exceeds the stated sample mass, and the sample mass changes at the control. These inconsistencies prevent a reliable quantitative comparison for those points. No overall reduction percentage is calculated.
What was observed on site
The report concludes that substantial drying was observed. It also requests repairs to the roof and rainwater drainage, along with action on lateral water entry and splashback. These recommendations are part of the case and should accompany any presentation of its readings.
From this reference to your own building
Start with the cause of the damp. Marks near the floor, salts and damaged finishes need to be considered together with the construction and the history of water entry. A leaking pipe, rainwater penetration and condensation require their own investigation. Send a plan and dated photographs, and describe the wall materials and the affected areas. These details help relate a device’s stated coverage to its intended position.
How do I use this report when choosing a device?
Use it as a record of this building and these inspections. Keep the original units and sampling conditions with the figures. A renovation photograph shows the appearance of a surface; it does not measure its water content. Do not infer an overall reduction from samples whose mass, depth or height changed.
Which Humidistop range should I compare?
ATE devices are electromagnetic and use mains electricity. ATG devices are geomagnetic and operate without a mains connection. Check the exact specification and installation instructions for the chosen reference. The model used on a historical site and a product currently offered for sale must remain clearly identified. The result observed in one building does not guarantee the result in another.
Can I repaint immediately after installation?
Plan the finishing work from the actual condition of the wall, suitable materials and any salts present. Allow the drying to be followed over time and address other water sources. A calendar date alone does not establish that a substrate is ready for a new coating.
Read more documented references
Source: Humidistop control report supplied for this reference. The entries and comparison limits above are retained from the document.