Saint-Égrève Church: readings from a STOP ONE ST60 follow-up

The following reference concerns a public building. It helps an owner understand what a documented wall-drying follow-up contains, before looking at the devices suitable for a separate property.

At Saint-Égrève, the local authority was the customer and the equipment was installed in the church nave. Installation is dated 23 November 2016. The control was signed in November 2018 and the report is labelled “24 months”.

Readings and sampling conditions

Original report entries, without recalculating a percentage
Sampling point Initial reading Control reading
West wall 5.6 1.2
Second west-wall point 13 2.5

The first point is headed “water weight per 20 g”. At the second point, the printed sample mass has been amended by hand to 19.9 g. Both samples are recorded at 30 cm above the floor and 20 cm deep, in stone and sand. The numbers are reproduced without converting them to percentages.

What was observed on site

The follow-up of the historical STOP ONE ST60 records lower values at both points. The report recommends, among other measures, removing cement before applying new plaster. The historical reference must remain distinct from current ATE products.

From this reference to your own building

Start with the cause of the damp. Marks near the floor, salts and damaged finishes need to be considered together with the construction and the history of water entry. A leaking pipe, rainwater penetration and condensation require their own investigation. Send a plan and dated photographs, and describe the wall materials and the affected areas. These details help relate a device’s stated coverage to its intended position.

How do I use this report when choosing a device?

Use it as a record of this building and these inspections. Keep the original units and sampling conditions with the figures. A renovation photograph shows the appearance of a surface; it does not measure its water content. Do not infer an overall reduction from samples whose mass, depth or height changed.

Which Humidistop range should I compare?

ATE devices are electromagnetic and use mains electricity. ATG devices are geomagnetic and operate without a mains connection. Check the exact specification and installation instructions for the chosen reference. The model used on a historical site and a product currently offered for sale must remain clearly identified. The result observed in one building does not guarantee the result in another.

Can I repaint immediately after installation?

Plan the finishing work from the actual condition of the wall, suitable materials and any salts present. Allow the drying to be followed over time and address other water sources. A calendar date alone does not establish that a substrate is ready for a new coating.

Read more documented references

Source: Humidistop control report supplied for this reference. The entries and comparison limits above are retained from the document.

Humidistop – Wall drying devices for rising damp
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.