The following reference concerns a public building. It helps an owner understand what a documented wall-drying follow-up contains, before looking at the devices suitable for a separate property.
The Lourenties Church report follows three walls between installation on 8 July 2014 and the control on 12 October 2015. It provides a documented reference for contractors, local authorities and building managers organising a similar follow-up.
Readings and sampling conditions
| Sampling point | Initial reading | Control reading |
|---|---|---|
| Rear wall | 7.8 gr/100 | 3.3 gr/100 |
| Right entrance wall | 8 gr/100 | 3.4 gr/100 |
| Left wall | 9.5 gr/100 | 2.5 gr/100 |
The values and units reproduce the report. Sample-mass headings and the stated units are not consistent, so no conversion to percentages or overall reduction is made. Samples are recorded at a depth of 20 cm, at a height of 48 cm for the rear wall and 40 cm for the other walls.
What was observed on site
The report describes lower readings and drying in progress. It also notes lateral water entry, a damaged gutter and standing water that need to be addressed separately. These observations belong in the case presentation alongside the table.
From this reference to your own building
Start with the cause of the damp. Marks near the floor, salts and damaged finishes need to be considered together with the construction and the history of water entry. A leaking pipe, rainwater penetration and condensation require their own investigation. Send a plan and dated photographs, and describe the wall materials and the affected areas. These details help relate a device’s stated coverage to its intended position.
How do I use this report when choosing a device?
Use it as a record of this building and these inspections. Keep the original units and sampling conditions with the figures. A renovation photograph shows the appearance of a surface; it does not measure its water content. Do not infer an overall reduction from samples whose mass, depth or height changed.
Which Humidistop range should I compare?
ATE devices are electromagnetic and use mains electricity. ATG devices are geomagnetic and operate without a mains connection. Check the exact specification and installation instructions for the chosen reference. The model used on a historical site and a product currently offered for sale must remain clearly identified. The result observed in one building does not guarantee the result in another.
Can I repaint immediately after installation?
Plan the finishing work from the actual condition of the wall, suitable materials and any salts present. Allow the drying to be followed over time and address other water sources. A calendar date alone does not establish that a substrate is ready for a new coating.
Read more documented references
Source: Humidistop control report supplied for this reference. The entries and comparison limits above are retained from the document.